Oil-Cooled Chiller is a type of cooling system that utilizes oil as a heat transfer medium instead of water or refrigerants. These chillers are often employed in industrial applications or specialized settings where high thermal efficiency and reliability are essential.
◎ The cooling medium is oil
◎ Low noise fan motor
◎ Stable operation, power saving and durable
◎ Multiple security protection
◎ Normal temperature adjustable 5-35°C
◎ The cooling medium is oil
◎ Low noise fan motor
◎ Stable operation, power saving and durable
◎ Multiple security protection
◎ Normal temperature adjustable 5-35°C
◎ Can be customized according to specific needs
◎ The models of air-cooled chiller, water-cooled chiller and screw chiller can be customized
| Oil-Cooled Chiller | ||||
| Custom series | Hytau®OCC-AC | Hytau®OCC-WC | Hytau®OCC-AC-S | Hytau®OCC-WC-S |
| item | Air cooling oil machine | Water cooling oil machine | Air-cooled screw oil machine | Water-cooled screw oil machine |
A
The models of air-cooled chiller, water-cooled chiller and screw chiller can be customized

| 1. Condenser | 2. Cooling fan | 3. Angle valve |
| 4. Drying filter | 5. Expansion valve | 6. Automatic water makeup nozzle |
| 7. Drain valve | 8. High pressure Switch | 9. Low pressure switch |
| 10. Compressor | 11. Evaporator | 12. Bypass valve (regulating valve) |
| 13. Pump | 14. Cooling water return | 15. Cooling water outlet |
As shown in the figure above , the refrigerant liquid with low temperature and low pressure flows in the evaporator tube and contacts with water outside ,forming refrigerant , which indirectly absorbs the heat of water, makes the water temperature drop, and the refrigerant absorbs the heat of water, which makes the refrigerant gasified and changes from liquid to gas. Through the suction of the compressor , the refrigerant is sucked into the compressor and compressed into the high temperature and high pressure gas system The refrigerant is discharged. After passing through the condenser, due to the function of the fan, the air rapidly cools the refrigerant in the condenser tube . The refrigerant changes from a gaseous state to a liquid state , into a liquid with high temperature and high pressure . After passing through the throttling device, the refrigerant turns into a low-pressure and low-temperature liquid refrigerant and enters the evaporator for a cycle . Through a series of cycle refrigeration , the circulating water pump directly transports the cooling water to the using equipment and returns to the evaporator water tank after cooling down, so as to cycle repeatedly.
B

| 1. Cooling water tower | 2. Circulating pump of water tower | 3. Angle valve |
| 4. Drying fiter | 5. Expansionvalve | 6. Automatic water makeup nozzle |
| 7. Condenser | 8. High pressure switch | 9. Low pressure switch |
| 10. Compressor | 11. Evaporator | 12.Bypass valve (regulating valve) |
| 13. Refrigerated water pump | 14. Cooling water return | 15. Cooling water outlet |
| 16. Drain valve | 17. Cooling water outlet | 18. Cooling water inlet |

◎ Tips:The type and model of the machine are different, so the selection and appearance of accessories are also slightly different
| Multiple protections-alert | |||
| 1.Temperature abnormalities | 2.The power phase inversion | 3.High- and low-pressure failure | 4.Overload of compressor |
| 5.Overheat of compressor | 6.The pump is overloaded | 7.Low water level alarm | 8.Short circuit |
| 9.Overload of current | 10.Protection against freezing | 11.Exhaust pressure protection | 12.Excellent water flow protection |

Copy product links